Exhaust / Purifier 8 Seat Teppanyaki Grill Table , Japanese Restaurant Grill Table
Why choose Chuanglv GREENARK Teppanyaki?
a. . Electromagnetic (Induction) Teppanyaki:
1) The only manufacturer in China who specially designed and assembles electromagnetic plate and motor for teppanyaki equipment;
2) German Infinon power module and NEC rectifier;
3) The circuit board material is in conformity with UL and ROHS certification, the master chip is with imported 32's DSP digital processing unit, and the 6-layered heat resistant insulative material makes the motor work for a much longer time;
4) Electromagnetic radiation is only 18k-35k, which is much lower than the European standard limit of 100k.
b. Gas Teppanyaki:
1) Gas consumption: LPG 0.29m3/h (0.6kgs), pipeline gas 0.8m3/h.
2) Thermostat control, automatic electronic ignition device, automatic flame failure protection device.
c. Built-in Air Blower: High temperature resistant; low noise.
d. Built-in Taiwan Electrostatic Fume Precipitator:
1) Absorbing fume particles with diameter of over 0.1 um (diameter) with processing efficiency of 93%-97%;
2) High and low voltage dust collecting plate separation technology, easy for cleaning;
3) Advanced point discharging technology;
4) Power-off protection device for output disorder.
Comparison Of Three Heating Methods |
Heating Method |
Electromagnetic/Induction |
LPG |
Pipeline Natural Gas |
Regular Parameter |
380v/50hz/8kw/3-Phase |
8kw(≈18mj/m³) |
8kw(≈33mj/m³) |
Rated Pressure |
/ |
2800pa±500pa |
2000pa±10% |
Consumption |
8kwh |
0.29m³/0.6kgs/h |
0.8m³/h |
Cooking Area |
450*400mm |
φ500mm |
φ500mm |
Enlarged Cooking Area |
600*400mm |
/ |
/ |
Temp Rising |
6min to Reach 260℃ |
15min to Reach 260℃ |
15min to Reach 260℃ |
Temp Difference Between Real Temp & Indicator Temp |
±1℃ |
±20℃ |
±20℃ |
Homeothermy |
Good |
Poor |
Poor |
Adventage |
Safe, high efficiency, easy operation and temperature control; electromagnetic radiation only 18-30k |
Thermostat control, automatic electronic ignition device, automatic flame failure protection device |